PV Input
7.5 - 20KW
Working Mode
On/Off Grid
Battery Mode
48V
Grid Type
Three Phase
Protection
1P65
XYLUCK-G 5KW-14KW hybrid inverter is a three phase multi-mode string inverter with low voltage battery backup. It is compatible for residential/small businesses power applications. It can manage power input from both solar power system and battery storage system to ensure the most efficient use of solar energy, increase self-energy source, grid independence, and reduce your electricity bills. XYLUCK inverter has two AC inputs, therefore AC diesel generator could be connected as a second source of backup power to achieve the optimum of output power consistency. This series of hybrid inverters are produced by sunover in sizes, 5kw, 6kw, 8kw, 10kw, 12kw, 14kw output power with three phase grid type. It could be connected upto 20 units in parallel, either of the same size or different sizes of units.
XYLUCK-G hybrid inverter - Data sheet
Model | XYLUCK-5G-48 XYLUCK-6G-48 XYLUCK-8G-48 XYLUCK-10G-48 XYLUCK-12G-48 XYLUCK-14G-48 |
Battery Input |
|
Battery Type | Lead-acid or Li-Lon |
Battery Voltage Range (V) | 40-60 |
Max. Charge Current (A) | 120 130 200 220 250 280 |
Max. Discharge Current (A) | 120 130 200 220 250 280 |
Charging Curve | 3 Stages/Equalization |
External Temperature Sensor | Optional |
Charging Strategy for Li-Ion Battery | Self-Adaption to BMS |
PV String Input |
|
Max. DC Input Power (W) | 7500 9000 12000 16000 18000 21000 |
PV Input Voltage (V) | 650(160~800) |
MPPT Range (V) | 200~700 |
Full Load DC Voltage Range (V) | 260~650 |
Start-up Voltage (V) | 160 |
PV Input Current (A) | 17+17 17+17 17+17 26+17 26+17 26+17 |
Max. PV Isc (A) | 17+17 17+17 17+17 26+17 26+17 26+17 |
No. of MPPT Trackers | 2 |
No. of Strings per MPPT Trackers | 1+1 1+1 1+1 1+1 1+1 1+1 |
AC Output |
|
Rated AC Output and UPS Power (W) | 5000 6000 8000 10000 12000 14000 |
Max. AC Output Power (W) | 6000 7200 9600 13200 14000 15400 |
Peak Power (off grid) | 2 times of rated power, 10s 1.8 times of rated power, 10s |
AC Output Rated Current (A) | 7.6/7.3 9.1/8.7 12.1/11.6 15.2/14.5 18.2/17.4 21.1/20.3 |
Max. AC Current (A) | 11.4/10.9 13.6/13 18.2/17.4 22.7/21.7 27.3/26.1 27.6/26.4 |
Max. Continuous AC Passthrough (A) | 38 40 42 44 44 45 |
Power Factor | 0.8 leading to 0.8 lagging |
Output Frequency and Voltage (V) | 50/60Hz, 380/400Vac (Triple phase) |
Grid Type | Three phase |
Current Harmonic Distortion | THD<3%(Linear load<1.5%) |
Efficiency |
|
Max. Efficiency | 97.90% |
Euro Efficiency | 96.90% |
MPPT Efficiency | 99.90% |
Protection |
|
Integrated | PV Input Lightning Protection, Anti-islanding Protection, PV String Input Reverse Polarity Protection, InsulationResistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection |
PV Arc Fault Detection | Optional |
Output Over Voltage Protection | DC Type II/AC Type III |
Certifications and Standards |
|
Grid Regulation | CEI 0-21, VDE-AR-N 4105, NRS 097, IEC 61727, G99, G98, VDE 0126-1-1, RD 1699,C10-11 |
Safety Regulation | IEC/EN62109-1, IEC/EN62109-2 |
EMC | IEC/EN 61000-6-1,IEC/EN 61000-6-2, IEC/EN 61000-6-3, IEC/EN 61000-6-4 |
General Data |
|
Operating Temperature Range (℃) | -45~60, >45 Derating |
Cooling | Smart Cooling |
Noise (dB) | ≤45 |
Communication with BMS | RS485, CAN |
Weight (kg) | 38 40 42 44 44 45 |
Dimensions (mm) | 510Wx630Hx290D |
Protection Degree | IP65 |
Installation Style | Wall-mounted |